{"id":920,"date":"2022-07-15T02:49:50","date_gmt":"2022-07-15T02:49:50","guid":{"rendered":"https:\/\/help.noritz.com\/?post_type=ht_kb&#038;p=920"},"modified":"2022-07-15T02:49:51","modified_gmt":"2022-07-15T02:49:51","slug":"error-code-20","status":"publish","type":"ht_kb","link":"https:\/\/help.noritz.com\/index.php\/knowledge-base\/error-code-20\/","title":{"rendered":"Error Code 20"},"content":{"rendered":"\n<p><strong>EC20 or Error Code 20<\/strong><\/p>\n\n\n\n<p>The error code 20 means the High Limit Switch has been triggered. This error code generally requires a hard reset (unplugging or disconnecting power). The high limit switch is usually found on an elbow of copper heat exchangers or on the copper pipe leaving the heat exchanger in a Pre-Mix style unit.<\/p>\n\n\n\n<p>The purpose of the high limit switch is to trip if water temperature in or leaving the heat exchanger approaches 176F to 205F, well into the dangerous scalding range and just a bit below the boiling point.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"803\" height=\"418\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/image_2022-07-14_192146686.png\" alt=\"\" class=\"wp-image-921\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/image_2022-07-14_192146686.png 803w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/image_2022-07-14_192146686-300x156.png 300w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/image_2022-07-14_192146686-768x400.png 768w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/image_2022-07-14_192146686-50x26.png 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/image_2022-07-14_192146686-60x31.png 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/image_2022-07-14_192146686-100x52.png 100w\" sizes=\"auto, (max-width: 803px) 100vw, 803px\" \/><figcaption>3 different high limit switches with 80C, 94C and 96C trip temperatures.<\/figcaption><\/figure>\n\n\n\n<p>Smaller units will generally have lower trip temperatures while larger units and commercial units will have higher trip temperatures. Once the high limit switch is triggered combustion stops immediately and the unit will close the water control servo to prevent super heated water from leaving the unit and entering the plumbing.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"665\" height=\"612\" data-id=\"922\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/EZHLS.jpg\" alt=\"\" class=\"wp-image-922\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/EZHLS.jpg 665w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/EZHLS-300x276.jpg 300w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/EZHLS-50x46.jpg 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/EZHLS-60x55.jpg 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/EZHLS-100x92.jpg 100w\" sizes=\"auto, (max-width: 665px) 100vw, 665px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"295\" height=\"225\" data-id=\"923\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/NRHLS.jpg\" alt=\"\" class=\"wp-image-923\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/NRHLS.jpg 295w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/NRHLS-50x38.jpg 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/NRHLS-60x46.jpg 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2022\/07\/NRHLS-100x76.jpg 100w\" sizes=\"auto, (max-width: 295px) 100vw, 295px\" \/><\/figure>\n<\/figure>\n\n\n\n<p>The most common cause of an error code 20 (and most other overheat related codes) is scale build up in the heat exchanger. Scale build up reduces the heat transfer into the water passing through the heat exchanger. Reduced heat transfer into the water means other parts retain the heat and eventually overheat. If you repeatedly get error codes 20 and just reset the unit without investigating and resolving the issue, you&#8217;re likely to end up with an <a rel=\"noreferrer noopener\" href=\"https:\/\/help.noritz.com\/index.php\/knowledge-base\/error-code-14\/\" target=\"_blank\">error code 14<\/a> which is not resettable and requires a much more involved repair process.<\/p>\n\n\n\n<p>Additional causes could be related to poor combustion, obstructions in the venting preventing removal of hot exhaust, a loose wiring connection and of course a failed high limit switch. If there is a bad wiring connection of the high limit switch to the main wire harness or a failed high limit switch, usually the error code will not reset even if the unit is cold. If the high limit switch and wiring is good, you can usually unplug the unit and let it cool down for awhile and when you plug it back in the code will be reset and the unit will attempt to operate normally. If the root cause of the overheat still exists, the code will eventually return.<\/p>\n\n\n\n<p>In general, inspect the overall condition and cleanliness of the unit. If the unit is installed in an area with hard water and there is no softener, water treatment or records of descale flushes being performed it would be a good place to start by conducting a full service. Start by performing a descale flush and if the unit has signs of dust, dirt or lint build up also perform a combustion cleaning.<\/p>\n\n\n\n<p>Descale procedures can be found in the installation\/owners manual, on our <a href=\"https:\/\/support.noritz.com\" target=\"_blank\" rel=\"noreferrer noopener\">Support Site<\/a> and on our <a href=\"https:\/\/www.youtube.com\/noritzamerica\" target=\"_blank\" rel=\"noreferrer noopener\">YouTube Page<\/a> along with a general maintenance video.<\/p>\n\n\n\n<p><strong>For further technical assistance call 866-766-7489 or use our\u00a0<a rel=\"noreferrer noopener\" href=\"https:\/\/contractorfinder.noritz.com\/contractors?installer=false&amp;servicer=true\" target=\"_blank\">Contractor Locator<\/a>\u00a0to find a local service representative.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>EC20 or Error Code 20 The error code 20 means the High Limit Switch has been triggered. This error code generally requires a hard reset (unplugging or disconnecting power). The high limit switch is usually found on an elbow of copper heat exchangers or on the copper pipe leaving the&#8230;<\/p>\n","protected":false},"author":4,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"footnotes":""},"ht-kb-category":[26],"ht-kb-tag":[28],"class_list":["post-920","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-error-codes","ht_kb_tag-errorcodes"],"_links":{"self":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb\/920","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/comments?post=920"}],"version-history":[{"count":3,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb\/920\/revisions"}],"predecessor-version":[{"id":926,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb\/920\/revisions\/926"}],"wp:attachment":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/media?parent=920"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb-category?post=920"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb-tag?post=920"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}