{"id":79,"date":"2021-04-10T20:22:47","date_gmt":"2021-04-10T20:22:47","guid":{"rendered":"https:\/\/knowall.dev19.bigideas.io\/?post_type=ht_kb&#038;p=79"},"modified":"2022-09-01T02:20:08","modified_gmt":"2022-09-01T02:20:08","slug":"install-remote","status":"publish","type":"ht_kb","link":"https:\/\/help.noritz.com\/index.php\/knowledge-base\/install-remote\/","title":{"rendered":"How to install an external remote"},"content":{"rendered":"\n<p><strong>This article will detail the installation of a remote accessory on the Noritz tankless water heater.<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-to-install-remotes-most-units\">How to Install Remotes (Most Units)<\/h3>\n\n\n\n<p>To locate the directions for your specific model, please download your installation manual here: <a href=\"https:\/\/support.noritz.com\/technical-literature\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/support.noritz.com\/technical-literature<\/a><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"424\" height=\"319\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188.png\" alt=\"\" class=\"wp-image-80\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188.png 424w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-300x226.png 300w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-50x38.png 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-60x45.png 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-100x75.png 100w\" sizes=\"auto, (max-width: 424px) 100vw, 424px\" \/><figcaption><em>Figure 1. Remote controller and remote control Cord<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\"><br><strong>Considerations on the installation location:<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>The remote should be installed in an easily accessible location.<\/li><li>Avoid installing in a place where the water or steam can come into contact with the controller.<\/li><li>Avoid locations where special chemical agents (e.g., benzene, fatty and oily detergents) are used.<\/li><li>Avoid outdoor installation, or installation in an indoor location where it will be exposed to direct sunlight.<br><\/li><\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"157\" height=\"145\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-1.png\" alt=\"\" class=\"wp-image-81\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-1.png 157w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-1-50x46.png 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-1-60x55.png 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-1-100x92.png 100w\" sizes=\"auto, (max-width: 157px) 100vw, 157px\" \/><figcaption><em>Figure 1a. Remote control cord<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Connection of the Remote Controller Cord<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>White Connector -&gt; To Remote Controller (Figure 1.)<\/li><li>Y-Shaped terminals-&gt;To Water heater (Figure 1.)<\/li><li>A 26\u2019 cord can be purchased separately (Part# RC-CORD26)<\/li><\/ul>\n\n\n\n<p class=\"wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon is-style-info\"><em><strong>Confirm the connection with the labels at both ends of the remote controller cord.<\/strong><\/em><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>The remote controller cord can be extended up to 300 ft. by splicing the cord and using 18 gauge wire to extend the cord to the appropriate length.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Types of Remote Terminal Blocks:<\/h2>\n\n\n\n<p><strong>External connection terminal block type (current and newer models):<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"267\" height=\"201\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/External.png\" alt=\"\" class=\"wp-image-82\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/External.png 267w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/External-50x38.png 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/External-60x45.png 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/External-100x75.png 100w\" sizes=\"auto, (max-width: 267px) 100vw, 267px\" \/><\/figure>\n\n\n\n<p>1. Check to make sure that the remote controller cord has plenty of slack in order to reach the external connection terminal block.<\/p>\n\n\n\n<p>2. Disconnect electrical power to the water heater.<\/p>\n\n\n\n<p>3. Remove the single screw securing the terminal block cover and then remove the cover.<\/p>\n\n\n\n<p>4. Pass the remote controller cord through the wiring throughway and connect the Y terminals at the end of the remote controller cord to the terminal block. <strong>Pick either the screw set on the left or on the right, do not connect one to each side.<\/strong><\/p>\n\n\n\n<p>5. Replace the terminal block cover and install the screw previously removed in step 3<\/p>\n\n\n\n<p>6. Reconnect electrical power to the water heater.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"circuit-board-mounted-terminal-block-current-small-units\">Circuit board mounted terminal block (Current small units):<\/h2>\n\n\n\n<p>(NRC661, NRC663 [EZTR40], NRC711, NR501, NR662)<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>Check to make sure that the remote controller cord has plenty of slack in order to reach the terminals inside the unit.<\/li><li>Disconnect electrical power to the water heater.<\/li><li>Remove the 4 screws securing the front cover and take of the cover.<\/li><li>Locate the circuit board along the bottom of the unit and lift the plastic flap covering it (image 1).<\/li><li>Pass the remote controller cord through the wiring throughway and connect the Y terminals at the end of the remote controller cord to the terminal block circled below (image 2).<\/li><li>Replace the front cover and the 4 screws.<\/li><li>Reconnect electrical power to the water heater.<\/li><\/ol>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"406\" height=\"293\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Flap.jpg\" alt=\"\" class=\"wp-image-83\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Flap.jpg 406w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Flap-300x217.jpg 300w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Flap-50x36.jpg 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Flap-60x43.jpg 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Flap-100x72.jpg 100w\" sizes=\"auto, (max-width: 406px) 100vw, 406px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"454\" height=\"307\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Terminals.jpg\" alt=\"\" class=\"wp-image-84\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Terminals.jpg 454w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Terminals-300x203.jpg 300w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Terminals-50x34.jpg 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Terminals-60x41.jpg 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Terminals-100x68.jpg 100w\" sizes=\"auto, (max-width: 454px) 100vw, 454px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"internal--circuit-board-mounted-terminal-block-type-older-units\">Internal &amp; Circuit board mounted terminal block type (older units):<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Leave enough slack so that the remote controller cord will not be damaged if the unit is removed from the wall.<\/li><li>Remove the front cover of the heater (4 screws).&nbsp;<\/li><li>Pass the remote controller cord through the wiring throughway and into the unit.<\/li><li>Connect the Y terminals at the end of the remote controller cord to the terminal block (see images below).<\/li><li>Secure the remote controller cord with a clamp.<\/li><li>Replace the front cover.<\/li><\/ol>\n\n\n\n<p><strong>Internal terminals mounted next to the GFCI:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"221\" height=\"148\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-2.png\" alt=\"\" class=\"wp-image-85\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-2.png 221w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-2-50x33.png 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-2-60x40.png 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/encoded-image-1498174188-2-100x67.png 100w\" sizes=\"auto, (max-width: 221px) 100vw, 221px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"227\" height=\"170\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Int_term1.png\" alt=\"\" class=\"wp-image-86\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Int_term1.png 227w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Int_term1-50x37.png 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Int_term1-60x45.png 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/Int_term1-100x75.png 100w\" sizes=\"auto, (max-width: 227px) 100vw, 227px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/int_term2.png\" alt=\"\" class=\"wp-image-87\" width=\"230\" height=\"174\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/int_term2.png 230w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/int_term2-50x38.png 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/int_term2-60x45.png 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/int_term2-100x76.png 100w\" sizes=\"auto, (max-width: 230px) 100vw, 230px\" \/><\/figure>\n\n\n\n<p><strong>Circuit Board Mounted Terminal Screws<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"230\" height=\"173\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB_Term.png\" alt=\"\" class=\"wp-image-88\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB_Term.png 230w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB_Term-50x38.png 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB_Term-60x45.png 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB_Term-100x75.png 100w\" sizes=\"auto, (max-width: 230px) 100vw, 230px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Video Walk-through<\/h2>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Connecting a Noritz Remote Control\" width=\"643\" height=\"362\" src=\"https:\/\/www.youtube.com\/embed\/OBmjhHiOxvg?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>This article will detail the installation of a remote accessory on the Noritz tankless water heater. How to Install Remotes (Most Units) To locate the directions for your specific model, please download your installation manual here: https:\/\/support.noritz.com\/technical-literature Considerations on the installation location: The remote should be installed in an easily&#8230;<\/p>\n","protected":false},"author":1,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"footnotes":""},"ht-kb-category":[2,18],"ht-kb-tag":[25],"class_list":["post-79","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-technical-tips","ht_kb_category-accessory-products","ht_kb_tag-accessories"],"_links":{"self":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb\/79","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/comments?post=79"}],"version-history":[{"count":3,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb\/79\/revisions"}],"predecessor-version":[{"id":933,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb\/79\/revisions\/933"}],"wp:attachment":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/media?parent=79"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb-category?post=79"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb-tag?post=79"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}