{"id":367,"date":"2021-04-17T08:43:28","date_gmt":"2021-04-17T08:43:28","guid":{"rendered":"https:\/\/knowall.dev19.bigideas.io\/?post_type=ht_kb&#038;p=367"},"modified":"2021-04-17T08:43:29","modified_gmt":"2021-04-17T08:43:29","slug":"thermostat-cb","status":"publish","type":"ht_kb","link":"https:\/\/help.noritz.com\/index.php\/knowledge-base\/thermostat-cb\/","title":{"rendered":"Where do I connect the thermostat on the CB180 or CB199?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Thermostat T-T connection, CB180-DV, CB199-DV<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The thermostat (T-T) is wired to CN15 on the circuit board as shown on page 34 of the installation manual (found here: <a href=\"http:\/\/support.noritz.com\/technical-literature.php\" rel=\"noreferrer noopener\" target=\"_blank\">http:\/\/support.noritz.com\/technical-literature.php<\/a>). See image 1 below. <strong>DO NOT<\/strong> connect your thermostat T-T to the &#8220;Heat Demand Input&#8221; connection next to the Display Panel (Image 2).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"image-1\">Image 1:<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"754\" height=\"566\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT.jpg\" alt=\"\" class=\"wp-image-368\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT.jpg 754w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT-300x225.jpg 300w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT-50x38.jpg 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT-60x45.jpg 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT-100x75.jpg 100w\" sizes=\"auto, (max-width: 754px) 100vw, 754px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Image 2:<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"592\" height=\"440\" src=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT-NO.jpg\" alt=\"\" class=\"wp-image-369\" srcset=\"https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT-NO.jpg 592w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT-NO-300x223.jpg 300w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT-NO-50x37.jpg 50w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT-NO-60x45.jpg 60w, https:\/\/help.noritz.com\/wp-content\/uploads\/2021\/04\/CB-TT-NO-100x74.jpg 100w\" sizes=\"auto, (max-width: 592px) 100vw, 592px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Thermostat T-T connection, CB180-DV, CB199-DV The thermostat (T-T) is wired to CN15 on the circuit board as shown on page 34 of the installation manual (found here: http:\/\/support.noritz.com\/technical-literature.php). See image 1 below. DO NOT connect your thermostat T-T to the &#8220;Heat Demand Input&#8221; connection next to the Display Panel (Image&#8230;<\/p>\n","protected":false},"author":1,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"footnotes":""},"ht-kb-category":[93],"ht-kb-tag":[],"class_list":["post-367","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-cb-combi"],"_links":{"self":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb\/367","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/comments?post=367"}],"version-history":[{"count":1,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb\/367\/revisions"}],"predecessor-version":[{"id":370,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb\/367\/revisions\/370"}],"wp:attachment":[{"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/media?parent=367"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb-category?post=367"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/help.noritz.com\/index.php\/wp-json\/wp\/v2\/ht-kb-tag?post=367"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}