1. Home
  2. Pro Series Descale Procedure

Pro Series Descale Procedure

If you do not have a Pro Series unit, CLICK HERE for the descale procedures for other Noritz units.

Equipment Needed

A descale flush involves circulating a diluted Calcium, Lime, and Rust remover product or pure food grade white vinegar through the heat exchanger using a submersible pump.  You will need the following equipment to conduct a descale:

  • 5 Gallon Bucket 
  • 1/6th HP or stronger Submersible pump 
  • Isolator valve kit (installed on heater) 
  • Water line connections (the isolator valves have a 3/4″ hose thread connections on their flush ports)
  • Descaling solution (Diluted Calcium, Lime, Rust remover product or pure food grade white vinegar)

We offer a Descale Kit that includes the bucket, submersible pump and hoses.

Preparing to Descale

  • Keep the unit connected to power.
  • Close the gas supply valve.
  • Close the water inlet valve and the water outlet valve. EZ Pro models will be on top of the unit, NRCR and NCC199CDV models will be underneath the unit. For NRCR models, also close the valve on the return water connection.
  • Connect one end of the hose to the cold water service port and the other end to the output connection of the submersible pump. Place the pump in the bucket.
  • Connect the other hose to the hot water service port and place the other end in the bucket.
  • Create a 50/50 mix of water and a calcium, lime, rust remover, minimum of 2 gallons total (ie: 1 gallon water and 1 gallon calcium, lime, rust remover). Alternatively, 2-3 gallons of pure food grade white vinegar is acceptable.
  • Open the valves on the cold and hot water service ports (NOT the main cold inlet and hot outlet valves).
  • Start Flush Mode with either the EZ Start Plus app or the Operation Panel as described below.

Flush Mode with EZ Start Plus App

  1. Open the EZ Start Plus app.
  2. Connect to the unit you wish to descale.
  3. Tap “Maintenance” on the bottom right.
  4. Tap “Scale Flushing” and follow steps to start flush mode.
  5. The operation panel should turn red and “Scale Flushing: — min” should be shown at the top.
  6. Proceed to “Performing Descale” section below.

Flush Mode with Operation Panel

  1. Press the power button to turn the display off.
  2. Press the menu button (3 horizontal lines).
  3. Press UP or DOWN arrow to “Scale Flushing” then press OK.
  4. Select “Start” and press OK button.
  5. The display should turn red and Scale Flushing in progress [– min] is shown.
  6. Proceed to “Performing Descale” section below.

Performing Descale

  • Confirm that the display shows “Scale Flushing in progress [– min]”.
  • Turn on the submersible pump to circulate the descale solution.
  • The display should change to [60 min]. Then the display will change to [59 min], [58 min] and so on as long as there is at least 1.5gpm of flow.
  • Once one hour has passed the display should show [00 min] and you can turn off the submersible pump.
  • If the display does not change from [– min], or the timer seems to stop before [00 min] is shown, check that the service port valves are fully open and make sure the pump is strong enough to maintain at least 1.5gpm through the entire descale.

Removing Solution from Heater

  • After the unit has been descaled for a full hour (timer reached 00 min), close the cold water service port and remove pump and hose from the bucket. Safely dispose of descale solution according to the directions of the solution you used.
  • If there is a sink or floor drain near by, put the hose end from the hot water service port in there to flush the remaining solution out. Slowly and carefully open the cold water inlet valve and flush out for at least 3 minutes, approximately 20 gallons worth.
  • If there is no sink or drain available, you can use the empty bucket. Put the hose end from the hot water service port into the empty bucket. Slowly and carefully open the cold water inlet valve to allow fresh water to flush out the remaining descale solution into the bucket. Do this for about 20 gallons worth. You will have to close the cold water inlet valve a few times to empty the bucket.
  • While fresh water is flushing through the unit, locate the drain plug(s) on your unit.
  • Carefully twist open those drain plugs for about 20 seconds each, then close. Use a bucket or large cup to catch the water.
  • Close the hot water service port valve after sufficient fresh water has been flushed through the unit.
  • Remove hoses from the hot and cold water service ports.

Finishing Descale

Ending Flush Mode with EZ Start Plus App:

  • Open the EZ Start Plus app.
  • Connect to the unit you were descaling.
  • Tap “Maintenance” on the bottom right.
  • Tap “Scale Flushing” and follow steps to stop flush mode.
  • The operation panel should turn blue.

Ending Flush Mode with Operation Panel:

  • Press OK button to STOP. The display should turn blue again.
  • Press BACK button to exit Scale Flushing mode, then BACK again to exit maintenance menu.
  • Press the power button to turn the display on.

Verifying Operation After Descale:

  • Open the hot water outlet valve.
  • Open the gas supply valve.
  • Confirm the unit is operating properly by running water at different flow rates.
Updated on November 20, 2026