EC16 or Error Code 16
The 16 error code occurs when the outlet water temperature spikes to an abnormally high value. The heater will restrict its water flow as an additional precaution. The error code is reset by unplugging the heater, waiting 20 seconds, and plugging it back in.
Common causes for the 16 error code are:
- Scale deposits1 in the heat exchanger2 and water components
- Improperly adjusted manifold3 pressures
- Wrong gas type
The following video demonstrates adjusting the manifold gas pressures. The proper manifold pressures can be found in the Service Manual for the unit you’re working on. Manifold gas pressures should only be adjusted by a trained and qualified service professional as incorrect settings could cause further issues or risk damage to the unit and/or property.
For further technical assistance call 866-766-7489 or use our Contractor Locator to find a local service representative. To download manuals, visit our support site: https://support.noritz.com/technical-literature
ARTICLE DEFINITIONS
Scale1
A hard mineral coating which forms on the surfaces of water piping. Scaling is more prevalent in areas with high water hardness.
Heat Exchanger2
A device used to transfer thermal energy between two or more fluids (e.g. air, water, oil). The fluids are typically separated and not allowed to mix.
Manifold3
A heater component which distributes gas to the burner plates