If the remote control or built in display is turned on, not showing an error code and you have a hot water faucet open, it likely means the unit is not detecting the flow for some reason. Common causes are:

  • The cold water inlet filter might be clogged. Debris in the pipes from installation can clog the filter or hard water and other mineral build up over time.
  • Reversed water connections: cold water supply connected to the hot water outlet, hot water supply line connected to cold water inlet. This is only relevant on a brand new installation. Double check that the cold and hot lines to the unit are plumbed correctly.
  • Cross connection: Cold water pressure is crossing over to the hot water plumbing where it shouldn’t, resulting in the water not actually moving through the unit. This is common at single handle fixtures with a mixing cartridge, a failed check valve on a recirculation return line or unfinished plumbing/fixtures in the building. Close the cold water valve feeding the heater and open up a fixture to the hot water side. Since the main feed to the hot water plumbing is cut off (the cold valve to the unit) there should be no water pressure on the fixture. The water should slow down to a trickle and eventually stop. If the water flow does not stop, then there is a cross connection somewhere in the plumbing.

If there is nothing on the display, verify that the heater is plugged in, the remote is plugged in (no damage to the wire), the outlet is receiving power, and the circuit breaker has not tripped.

If you see an error code (any number other than your normal set temperature) you can try resetting the unit by unplugging it for 20 seconds and plugging it back in.

A local Noritz Service Representative can be found on our Contractor Finder.